Model DPGT43HP.100, DPGT43HP.160 Differential Pressure Gauge with Output Signal

Brand: WIKA Instruments Ltd.

Wherever the differential pressure must be indicated locally and, at the same time, a signal transmission to the central control or remote centre is desired, the model DPGT43 intelliGAUGE® (patent, property right: e.g. DE 202007019025) can be used.
Features
  • High working pressure (static pressure) and high overpressure safety, optionally up to 40, 100, 250 or 400 bar.
  • Individual, non-linear characteristic curves (e. g. x2 or √x for flow measurement).
  • "Plug and play" with no configuration necessary.
  • Differential pressure measuring ranges from 0 … 60 mbar.
  • Hydraulic cushioning protection against rapid pressure changes.

Specifications

Version

  • Highest overload safety either side, pressure ratings PN 40, 100, 250 or 400, system fill fluid of the measuring cell acts as the dampening of the display
  • Overload resistance per EN 837-3.

Nominal Size in mm

  • 100
  • 160

Accuracy Class

  • 1.6
  • Option: 1.0 (application test required)
  • Option: 2.5 (Monel version)

Instruments with PN 40 & 100

  • 0 to 60 mbar to 0 to 160 mbar (measuring cell □ 140)
  • 0 to 0.25 bar to 0 to 40 bar (measuring cell □ 82)

Instruments with PN 250

  • 0 to 60 mbar to 0 to 250 mbar (measuring cell □ 140)
  • 0 to 0.4 bar to 0 to 40 bar (measuring cell □ 82)

Instruments with PN 400

  • 0 to 0.4 bar to 0 to 40 bar (measuring cell □ 86)
  • Dimensions of measuring cell from page 7 other units (e.g. psi, kPa) available or all other equivalent vacuum or combined pressure and vacuum ranges

Scale

  • Option: Scale layout with individual non-linear characteristic curves
  • Single scale
  • Option: Dual scale

Zero Point Setting

  • By means of adjustment appliance

Pressure Limitation

  • Observe the recommendations for the use of mechanical pressure measuring systems in accordance with EN 837-2
  • Fluctuating: 0.9 x full scale value
  • Steady: Full scale value

Overload Safety & Max. Working Pressure (Static Pressure)

  • Either side max. 40, 100, 250 or 400 bar

Connection Location

  • Option: Connection at 12 o‘clock
  • Option: Back mount
  • Lower mount (radial)

Process Connection

  • Differential Process connection per EN 61518 Other Process connections via female or male threads on request
  • 1/2" NPT Male
  • G ½ B male
  • G ½ B female

Permissible Temperature

  • Option: -40 ... +60° C (silicone oil filling)
  • Ambient: -20 ... +60° C
  • Medium: -20 ... +100° C

Temperature Effect

  • When the temperature of the measuring system deviates from the reference temperature (+20° C): max. ±0.5 %/10 K of Full Scale Value

Case Filling

  • Without
  • Option: With case filling

Documentation