Model 532.53+8xx Absolute Pressure Gauge with Switch Contact

Brand: WIKA Instruments Ltd.

Wherever the process pressure has to be indicated locally and, at the same time, circuits need to be switched, the model 532.5x switchGAUGE finds its use.
Features
  • High overload safety, long service life due to metal media chamber sealing
  • Media chamber protected against unauthorised access
  • Also available with liquid-filled case for high dynamic pressure loads or vibrations
  • Instruments with inductive contacts for use in hazardous areas
  • Instruments with switch contact for PLC applications

Specifications

Design

  • Mechanical absolute pressure gauge per DIN 16002

Nominal Size in mm

  • 100
  • 160

Accuracy Class

  • 1.6 (model 532.53)
  • Option:
  • 1.0 (model 532.52)
  • 2.5 (model 532.54)
  • The measurement accuracy is ensured for ambient pressure fluctuations between 955 and 1,065 mbar (min. and max. of atmospheric pressure)

Scale Ranges

  • 0 to 25 mbar 2) to 0 to 25 bar Absolute Pressure [0 to 0.36 psi to 0 to 3,600 psi Absolute Pressure]

Scale

  • Single scale
  • Option: Dual Scale

Pressure Limitation

  • Steady: Full scale value
  • Fluctuating: 0.9 x full scale value

Overload Safety

  • 10 x full scale value, max. 25 bar absolute pressure, min. 1 bar absolute pressure
  • Option: 20 x Full Scale Value, max. 25 bar Absolute Pressure, min. 1 bar Absolute Pressure

Process Connection with Lower Measuring Flange

  • Small flange for vacuum applications DN 10
  • Small flange for vacuum applications DN 16
  • Open connecting flange DN 25 PN 25, DIN 2501, form D per DIN 2526
  • Open connecting flange DN 25 PN 25 per EN 1092-1, form B
  • 1/2" NPT Female
  • 1/2" NPT
  • G ½ B

Permissible Temperature

  • Medium: +100° C [+212° F] maximum
  • Option: +200° C [+392° F] maximum
  • Ambient: -20 ... +60° C [-4 ... 140° F]
  • Option: -40 ... +60° C (silicone oil filling) ¹⁾

Temperature Effect

  • When the temperature of the measuring system deviates from the reference temperature (+20° C): max. ±0.8 %/10 K of Full Scale Value

Case

  • Option:,Safety version S3 per EN 837: With solid baffle wall (Solidfront) and blow-out back (models 532.32
  • 532.33, 532.34)
  • Instruments with liquid filling with compensating valve to vent case
  • Version S1 per EN 837: With blow-out device in case back

Case Filling

  • Without
  • Option: With silicone oil M50 case filling, ingress protection IP65 (models 533.52, 533.53, 533.54)

Wetted Materials

  • Diaphragm element (pressure element), ≤ 0.25 bar: Stainless Steel 316Ti, > 0.25 bar: NiCr Alloy (Inconel)
  • Media chamber with process connection: Stainless Steel 316L
  • Option: Wetted parts from Monel (models 56x.3x, 56x.5x)

Documentation